The FH-WC can control up to 8 zones on an underfloor heating system. Each zone can be operated independently to run the underfloor heating pump and fire your boiler.
FH-WC is a connection box for use in hydronic floor heating systems supplied from a manifold.
FH-WC is a wiring center for connecting thermal actuators to the room thermostats. It is provided with two potential-free relays for controlling a circulation pump and a boiler. The relays are activated when one or more thermostats require heat.
Technical specifications
FH-WC has 8 available outputs. FH-WC is connected to 230 VAC/50 Hz.
Mounting is made easy due to the symbols printed on the screw terminals.
Power supply
230 VAC ± 10%
Number of outputs
8
Output voltage
230 VAC
Max. load per output
3 W (max. 2 actuators per output)
Pump and boiler relay
Max. load 230 VAC (2A)
Ambient temperature
0 – 50° C
Transport temperature
-20 – 60° C
Enclosure
IP 20
Mains cable length
2m
Weight
1.5 kg
Internal fuse
F 4.0 A